ELANTAS aims for the highest quality of its products.
From formulation to end-use in the customers’ process, extensive test and measuring methods
are applied. In this way, constant material properties can be guaranteed.
Product name TI*** Viscosity* Gel time** Typical curing conditions Resins for universal use
ELAN-protect® EP 101 180 600 - 1.000 mPa·s 4 - 6 min 165 °C 4 - 6 h 140 °C or 2 - 4 h 165 °C ELAN-protect® UP 140 180 1.500 - 1.900 mPa·s 1.5 - 2.5 min 2 h 150 °C or 1 h 160 °C ELAN-protect® UP 141 200 850 - 1.150 mPa·s 5 - 7 min 130 °C 30 min - 1 h 160 °C ELAN-protect® UP 142 200 900 - 1.500 mPa·s 3 - 7 min 1 h 150 °C or 30 min 160 °C ELAN-protect® UP 142 TX 200 1.300 - 1.900 mPa·s 3 - 7 min 1 h 150 °C or 30 min 160 °C Quality laboratory
Resins for trickle and roll dip processes
• Viscosity
ELAN-protect® EP 201 180 • Geltime
2.500 - 3.500 mPa·s 5 - 7 min 130 °C 1 - 2 h 150 °C • Physical properties:
ELAN-protect® UP 240 A+B 200 density, solid 140 content,- 160 color
mPa·s 4 - 6 min 100 °C 30 min 160 °C • Chemical properties:
ELAN-protect® UP 242 200 amine value,1.000 acid - value,2.000
mPa·s 2 - 8 min 30 min 150 °C water content
ELAN-protect® UP 242 A + B 200 1.400 - 2.000 mPa·s 4 - 10 min 30 min 150 °C Resins for dip and hot dip processes
ELAN-protect® UP 142 UV 200 900 - 1.500 mPa·s 3 - 7 min 1 h 150 °C or 30 min 160 °C ELAN-protect® UP 343 220
6.000 - 9.000 mPa·s 8 - 12 min 1 h 150 °C (Provisional)
ELAN-protect® UP 343 UV ELAN-protect® UP 361 180 2.500 - 3.500 mPa·s 3 - 7 min 2 h 150 °C ELAN-protect®
Resins for VI and VPI processes
ELAN-protect® EP 410 200 700 - 1.400 mPa·s 50 °C 3 - 5 min 165 °C 12 h 165 °C ELAN-protect® EP 411 200 3.500 - 5.500 mPa·s 25 °C 3.5 - 5.5 min 165 °C 12 h 165 °C ELAN-protect® EP 412 200 4.000 - 6.000 mPa·s 25 °C 3 - 6 min 165 °C 12 h 165 °C ELAN-protect® EP 420 180 580 - 700 mPa·s 3 - 5 min 165 °C 6 - 12 h 165 °C ELAN-protect® EP 421 180 270 - 330 mPa·s 5 min bei 165 °C
Research &
Development
• Formulation
• Modification
• Continuous research
Technical Sales
• Technical expertise
• Advice on product selection
and application methods
• Project monitoring
Material testing
laboratory
• Measuring methods:
GA, DMA, GC, FTIR, DSC, TMA
• Temperature index:
mass loss, twisted pair,
helical coil
Application
laboratory
• Application methods:
trickle, dip, roll dip, vacuum (VI),
vacuum pressure (VPI), hot dip
with/without UV-supported curing
• Partial discharge
• Microscopy
3 - 4 h 180 °C (within system)
ELAN-protect® EP 425 180 1.700 - 2.600 mPa·s 4 - 6 min 165 °C 5 - 7 h 150 °C ELAN-protect® EP 426 180 3.000 - 5.500 mPa·s 6 - 10 min 165 °C 8 - 12 h 165 °C * measured at 23 °C or as mentioned
** measured at 120 °C or as mentioned
*** measured in accordance with IEC 61033 (helical coil)