Thin Film
Coating
What you need
is what you get.
Different dispensing head options of selective
coating systems are available to meet your
conformal coating needs.
Each BECTRON® grade differs. So the method of coating
has to differ, too. The range of options
enable you to apply BECTRON® with constant
accuracy and reproducibility.
The Film Coater is important for low viscosity
thin-film coating, such as widely used solvent-based
or VOC-free 100% solids systems.
Version 10/2017
Environmental
conditions
Testconditions Testmethod
Damp heat constant
T: +85 °C
humidity: 85 %
+85 °C ±2 °C at humidity = 85 % ± 2 %
duration time > 168 h
IPC-TM-650 2.6.3.3 (Flux)
IPC-SM-840C; Class T
Damp heat, alternating
temperature test cycles
T: +25 to +55 °C
humidity: 95 %
Environmental chamber
+25 °C to +55 °C ±2 °C
humidity 93 % +2%
-3%
exposure time 9 h at +55 °C
number of cycles (24 h) = 9
time of temperature changing 3 h
IEC 60068-2-30
GS 95003-4
VW 801 01
IPC-CC-830B
Alternating
temperature test
- 40 °C to +120 °C
-40 °C to +120 °C at ±2 °C
exposure time 30/45 min.
no. of cycles = 100, (500 typ); (3000)
time of temperature changing < 10 sec.
IEC 60068-2-14
GS 95003-4
VW 801 01
IPC-TM-650 2.6.7.1
IPC-CC-830B
BECTRON® Coating and Potting
Standard testing @ ELANTAS Europe
Bectron_Mappe_0910.indd 2